9-19、9-26 High pressure centrifugal fan
|
Date:2014-12-12 Update:2014-12-12 Views: |
|
|
Purpose:
QY9-19 type centrifugal fan is used for tobacco machinery dedicated fan, can be widely used in conveying material, conveying air and non-corrosive not spontaneous combustion, excluding the gas of viscous material. Medium temperature is generally not more than 50 degrees (highest do not exceed 80 degrees), the dust content in the medium and hard particles is not more than 150 mg/cubic meter.
QY9-19 no.4-6.3 - A Centrifugal fan selection table
Immediately No
|
Speed
r/min
|
Traffic
m3/h
|
Total pressure pa
|
Internal power
kw
|
The required power kw
|
4A
|
2900
|
824-1704
|
3253-3584
|
1.16-2.17
|
1.5-2.6
|
4.5A
|
2900
|
1174-2504
|
4112-4603
|
2.07-4.03
|
2.5-4.8
|
5A
|
2900
|
1610-3488
|
5080-5697
|
3.43-6.86
|
1.8-7.9
|
5.6A
|
2900
|
2262-4901
|
6400-7182
|
6.05-12.09
|
7.0-13.9
|
6.3A
|
2900
|
3220-6978
|
8148-9149
|
10.91-21.79
|
12.5-25.1
|
QY9-19No7.1-16DCentrifugal fan selection table
Immediately
No
|
Speedr
min
|
Traffic
m3/h
|
Total pressure
pa
|
Internal power kw
|
The required power
kw
|
7.1D
|
2900
|
4610-9988
|
10426-11717
|
19.83-39.62
|
23.3-46.3
|
8D
|
2900
|
6594-14287
|
13362-15229
|
36.02-71.95
|
42.3-84.4
|
8D
|
1450
|
3297-7144
|
3231-3620
|
4.5-8.99
|
5.5-10.6
|
9D
|
1450
|
4695-10171
|
4101-4597
|
8.11-16.21
|
9.5-19.0
|
10D
|
1450
|
6440-13952
|
4958-5941
|
13.38-29.88
|
15.7-35.1
|
11.2D
|
1450
|
9047-21713
|
6246-7491
|
23.58-57.66
|
27.7-61.8
|
11.2D
|
960
|
5990-14375
|
2705-3237
|
6.84-15.28
|
8.0-17.9
|
12.5D
|
1450
|
12577-30186
|
7822-9390
|
40.84-91.18
|
47.9-107.0
|
12.5D
|
960
|
8327-19985
|
3377-4043
|
11.85-26.46
|
13.9-31.1
|
14D
|
1450
|
17670-42409
|
9878-11874
|
71.97-160.69
|
84.5-188.6
|
14D
|
960
|
11699-28078
|
4249-5090
|
20.89-46.63
|
24.5-54.7
|
16D
|
1450
|
26377-63305
|
13035-15700
|
140.31-313.29
|
164.6-367.6
|
16D
|
960
|
17463-41912
|
5575-6683
|
40.72-90.92
|
47.8-106.7
|
QY9-26No4-6.3ACentrifugal fan selection table
Immediately
No
|
Speedr
/min
|
Traffic
m3/h
|
Total pressure
pa
|
Internal power
kw
|
The required power
kw
|
4A
|
2900
|
2198-3125
|
3407-3852
|
3.11-4.29
|
3.7-5.2
|
4.5A
|
2900
|
3130-3685
|
4256-4776
|
5.51-6.24
|
6.3-7.2
|
3963-4792
|
4256-4661
|
6.64-7.98
|
7.6-9.2
|
5A
|
2900
|
4293-6762
|
5180-6035
|
9.12-13.65
|
10.5-15.7
|
5.6A
|
2900
|
6032-7185
|
7400-7610
|
16.09-18.47
|
18.5-21.2
|
7766-9500
|
6527-7218
|
19.79-24.06
|
22.8-27.7
|
6.3A
|
2900
|
8588-11056
|
9195-9698
|
28.99-35.66
|
33.3-41.0
|
11883-13525
|
8310-8915
|
38.12-43.35
|
43.8-49.9
|
QY9-26No7.1-16DCentrifugal fan selection table
Immediately
No
|
Speed
r/min
|
Traffic
m3/h
|
Total pressure
pa
|
Internal power
kw
|
Therequiredpower
kw
|
|
|
7.1D
|
2900
|
12292-19360
|
10635-12427
|
52.7-78.82
|
61.8-92.5
|
|
8D
|
2900
|
17584-27696
|
13634-15955
|
95.72-143.14
|
112.3-168
|
|
8D
|
1450
|
8792-13848
|
3259-3834
|
11.96-17.89
|
14-21
|
|
9D
|
1450
|
12518-19717
|
4181-4869
|
21.56-32.24
|
25.3-37.8
|
|
10D
|
1450
|
17172-30052
|
5065-6143
|
35.69-59.34
|
41.9-69.6
|
|
11.2D
|
1450
|
24126-42221
|
6382-7747
|
62.90-104.58
|
73.8-122.7
|
|
11.2D
|
960
|
15973-27953
|
2763-3346
|
18.25-30.35
|
21.4-35.6
|
|
12.5D
|
1450
|
33540-58695
|
7993-9713
|
108.91-181.90
|
127.8-212.5
|
|
12.5D
|
960
|
22206-38860
|
3165-4179
|
31.61-52.56
|
37.1-61.7
|
|
14D
|
1450
|
47121-82463
|
10095-12285
|
191.94-319.16
|
225.2-374.5
|
|
14D
|
960
|
31197-54596
|
4341-5262
|
55.70-92.63
|
65.4-108.7
|
|
16D
|
1450
|
70039-123090
|
1332416250
|
374.22-622.26
|
439.1-730.2
|
|
16D
|
960
|
46569-81496
|
5696-6911
|
108.6-180.58
|
127.4-211.9
|
|
|
|
|